1) The use environment of UPS should pay attention to good ventilation, which is conducive to heat dissipation and keep the environment clean. 2) Do not bring inductive loads, such as money counters, fluorescent lamps, air conditioners, etc., to avoid damage to the uninterruptible power supply. 3) It is best to control the output load of UPS at about 60%, and the reliability is the highest. 4) UPS with too light load (such as 1000VA UPS with 100VA load) may cause deep discharge of the battery, which will reduce the service life of the battery and should be avoided as much as possible. 5) Proper discharge is helpful for the activation of the battery. For example, if the mains power is not stopped for a long time, the mains should be cut off artificially and the UPS should be discharged with load once every three months, which can prolong the service life of the battery. 6) For most small UPS, turn on the UPS after going to work, avoid starting the UPS with load when starting up, and turn off the UPS when leaving get off work; for the UPS in the network room, since most networks work 24 hours a day, the UPS must also run around the clock. 7) After the UPS is discharged, it should be charged in time to avoid damage to the battery due to excessive self-discharge. First, the use of skills Uninterruptible power supply - how to extend the power supply time of UPS? There are two ways to extend the power supply time of the uninterruptible power supply system: 1. External large-capacity battery pack: You can connect a battery pack with the corresponding capacity according to the required power supply time, but it should be noted that this method will cause a relative increase in the charging time of the battery pack, and will also increase the floor space and maintenance costs, so it needs to be carefully evaluated . 2. Purchase a large-capacity UPS system: This method can not only reduce maintenance costs, but also allow larger-capacity UPS to operate immediately if the load equipment is expanded. The UPS power system is turned on and off. Turn on for the first time (1) Turn on the power in the following order: the energy storage battery switch → the automatic bypass switch → the output switch is set to "ON" in turn. (2) Press the "ON" button on the UPS startup panel, the UPS power supply system will start slowly, the "inverter" indicator will be on, and after a delay of 1 minute, the "bypass" indicator will be off, and the UPS will switch to inverter power supply to complete the startup. After about 10 minutes of no-load operation, start the load according to the starting order of load power from small to large. Daily startup Just press the "ON" button on the UPS panel, and after about 20 minutes, the computer or other instruments can be turned on. Usually, the power switch of the load equipment can be turned on after the UPS starts to work stably (Note: the manual maintenance switch is in the "OFF" state when the UPS is running normally). Shutdown First turn off the computer or other instruments, let the UPS run for 10 minutes without load, after the heat in the standby is exhausted, then press the "OFF" button on the panel.

Manly Battery Co.,Ltd specializes in providing energy storage power, UPS backup power, power supply and new energy system solutions and operation and maintenance services for new energy, electric wheels, smart energy storage and green power applications. Among them, the field of network energy mainly includes communications, power, data centers, financial securities, rail transit, etc.; the field of smart energy storage mainly includes household energy storage, industrial and commercial energy storage, and microgrid energy storage systems; the field of green power mainly includes forklifts, low-speed electric vehicles, off-road vehicles, etc. At present, the main products are lithium-ion batteries and systems, lead-acid battery replacement lithium batteries and systems, and new energy system integration products and services. Please contact: sales@manlybatteries.com
info@manlybattery.com